Company Office Number:0755-27099734
Company landline:0755-27099734
Sales Mr. Chen:138 0270 8085
Sales Miss Hu:138 2351 9924
Company address:Room 403, Building A, No. 8 Xinhe Avenue, Xinqiao Community, Xinqiao Street, Bao'an District, Shenzhen
Email:facesun168@wickon.net
K2 furnace temperature tester, KIC furnace temperature tester, KIC K2 furnace temperature tester
The characteristics of furnace temperature tester K2:
Superior cost-effectiveness;
Small size and durable hardware;
Automatic triggering temperature technology;
Automatic temperature control program;
Automatic review and analysis of temperature curves;
Computer and mobile terminal, bidirectional temperature data acquisition technology.
Specification of furnace temperature tester K2:
Precision: | ±0.5℃ |
Resolution: | 0.1℃ |
Internal operating temperature: | 0 ℃ to 85 ℃ |
Sampling frequency: | 0.1 to 10 per second |
Data points: | 224,640 |
PC link: | USB2.0(Std-A/Mini-B) |
Power requirements: | (3) AAA battery |
Thermocouple compatibility (channels 7 and 9): | Standard K-type thermocouple |
Temperature range: | -150℃ to 1050℃ |
Dimensions (length x width x height mm): | 7 channels: 206.0 * 60.0 * 17.0 9 channels: 206.0 * 75.0 * 17.0 |
Insulation sleeve: | Refer to the specifications in the temperature resistance parameter table of the insulation sleeve below |
Copyright 2021 Shenzhen Shihan Electronic Technology Co., Ltd. Main website keywords:Furnace temperature tester,KIC furnace temperature tester, WICKON furnace temperature tester, DATAPAQ furnace temperature testerWebsite production: Shenzhen Shihan Technology