Is the KIC furnace temperature meter measuring abnormal peak soldering furnace temperature?

From a professional technical perspective, the KIC furnace temperature tester can measure temperature, indicating that there is no problem with the KIC furnace temperature tester. Where exactly is the problem?

1: Those who have used the KIC furnace temperature tester understand that there are three settings: trigger temperature, intermediate start temperature, and stop temperature. These three settings are generally located in the LOG folder of the installation file. Notepad can be used to open corrections. Usually, the KIC furnace temperature tester measures peak welding, with a system default value of 5 sampling frequency, a starting temperature of 110 degrees Celsius in the middle, and a stopping temperature of 90 degrees Celsius. The following are the settings parameters for wave soldering in the LOG folder of the KIC installation file: It is generally not recommended to modify them!


WAVE_SECTION=

SampleRatePerSecondForWAVE=5.000000

WaveMidpointTriggerTemperature=110.000000

WaveStopTriggerTemperature=90.000000

TEMPVsTIME_SECTION=

SampleRatePerSecondForTempVsTime=5.000000

WAVE_PROFILE_SECTION=

SampleRatePerSecondForWaveProfile=5.000000

WaveProfileMidpointTriggerTemperature=110.000000